<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">
Institutional Repository

Application of stemming plugs for the reduction of air blast induced during surface mine blasting

dc.contributor.advisorMulenga, Francoisen
dc.contributor.authorMushwana, Talenten
dc.date.accessioned2025-06-30T13:34:40Z
dc.date.available2025-06-30T13:34:40Z
dc.date.issued2024-11-11
dc.description.abstractThe use of stemming plugs with the intention of optimizing blast performance is gaining popularity in surface mining. This is because stemming plugs are purported to enhance energy retention and reduce the environmental impacts of blasting. The main objective of this study was to assess the potential of stemming plugs in reducing air blast at a quarry. The stemming plugs commercially known as Varistem® of diameter 102 mm were used for onsite testing. A total of 27 blasts were carried out under similar blast design conditions except for the stemming length that was varied between 1.9 and 3 m. The resultant air blast levels were recorded from two different monitoring stations around the pit. From the test programme, 15 blasts incorporated the Varistem® stemming plugs while the remaining 12 were conducted using standard stemming with aggregates only. The first monitoring station (i.e., Station A) was approximately 100 m away from the blast block while the second (i.e., Station B) was 700 m away. Data was collected from these two stations simultaneously for each of the 27 blasts. Using this arrangement, the data was modelled to correlated air blast and scaled distance. Finally, a comparison by statistical analysis was then carried out between the Varistem® blasts and the standard blasts. Results from Station A showed that 33% of the Varistem® blasts in contrast to 67% of the standard tests exceeded the regulatory threshold limit of 134 dB set by the United States Bureau of Mines (USBM). From Station B, all the Varistem® blasts were below the threshold while about 25% of the standard blasts were above the limit. The scaled depth of burial was also determined to estimate the level of blast energy containment. It was subsequently found that all Varistem® blasts were within the controlled energy range explaining why acceptable air blast levels were produced. Lastly, the empirical model by the USBM was found to describe the air blast of the quarry better than McKenzie’s model. In essence, the results produced from this study showed that the Varistem® stemming plugs are doing some work in reducing blast induced air blast compared to standard stemming methods. Nevertheless, on the body of knowledge, there exists no model specifically applicable to the Varistem® stemming plugs. There are also currently no guidelines available for the design of a blast involving Varistem® plugs in compliance with regulatory standards on air blast. Understanding the contribution of Varistem® stemming plugs to blasting operations is expected to add value to the body of knowledge by making available data for use by the scientific community.en
dc.description.degreeM. Sc. (Engineering)en
dc.description.departmentMining Engineeringen
dc.format.extent1 online resource (xvii, 169 leaves) : color illustrationsen
dc.identifier.urihttps://hdl.handle.net/10500/33507
dc.language.isoen
dc.subjectVaristem®en
dc.subjectAir blasten
dc.subjectStemming plugsen
dc.subjectBlastingen
dc.subjectUSBM modelen
dc.subjectMcKenzie’s modelen
dc.subjectSDG 9 Industry, Innovation and Infrastructureen
dc.subject.lcshBlasting -- Environmental aspectsen
dc.subject.lcshMines and mineral resources -- Safety measuresen
dc.subject.lcshMining engineering -- Technological innovationsen
dc.subject.otherUCTDen
dc.titleApplication of stemming plugs for the reduction of air blast induced during surface mine blastingen
dc.typeDissertationen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
dissertation_mushwana_t.pdf
Size:
5.7 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
53 B
Format:
Item-specific license agreed upon to submission
Description: